Home >> >>>Micro-Spectrophotometer IMS-1300

Micro-Spectrophotometer IMS-1300
Micro-Spectrophotometer IMS-1300

Catalogue number : 58080015-04

Micro-Spectrophotometer IMS-1300 allow instrument with a large concentration of nucleic acid range up to 10 to 15000 ng/μl(dsDNA), protein range up to 0.5 mg/ml to 400 mg/ml(BSA) without any samples dilution, with each measurement requiring less than 5 seconds with a pipette and wipe.


Availability : 3-4 Weeks

Availability : Availability : 3-4 Weeks

  • Product Information
  • Features
  • Technical Data

Micro-Spectrophotometer IMS-1230 allow instrument with a large concentration of nucleic acid range up to 10 to 15000 ng/μl(dsDNA), protein range up to 0.5 mg/ml to 400 mg/ml(BSA) without any samples dilution, with each measurement requiring less than 5 seconds with a pipette and wipe.

We offers dynamic full spectrum 200 nm, 230 nm, 260 nm, 280 nm detection to ensure exact results. Suitable for nucleic acids, proteins, cell cultures, microarray samples, and UV-VIS full spectrum absorbance scan with high accuracy and reproducibility.

Applications

  • Nucleic Acid: Concentration and purity of DS-DNA, SS-DNA and RNA
  • Protein: Concentration of the protein A280 (1Abs = 1mg/mL), BSA, IgG and lysozyme,  Concentration of protein with protein assay kit (Lowry, BCA and Bradford)
  • Cell Culture: Concentration of suspended cell cultures
  • UV-VIS:  UV/VIS full-spectrum (200 to 850 nm) absorbance scans
  • Microarray: Concentration of fluorescent dye labeled nucleic acid (microarray), for it can measure the concentration of the nucleic acid and the dye at the same time

  • Built-in Xenon flash lamp and touch display
  • Full spectrum 200 nm, 230 nm, 260 nm, 280 nm
  • Simple, less expensive, easy to use
  • Fast measurement time in less than 5 seconds.
  • The absorbance range is 0.002 to 75
  • Used 2048-element linear silicon CCD detector
  • Designed for micro-volume 0.3 to 2 µl samples
  • No dilutions required, even for high concentration sample

Model

IMS-1100

IMS-1200

IMS-1300

Wavelength range

200 to 850 nm

260 nm, 230 nm, 280 nm

Sample Volume

0.3 to 2 µL

Wavelength Accuracy

±1 nm

-

Wavelength Resolution

2nm (FWHM at Hg 546nm)

-

Source

Xenon flash lamp

Repeatability

 

 

 

Absorbance Range

0.002 to 75(optional: 150, 300, 10 mm equivalent absorbance)

0.2 to 75(10mm equivalent absorbance)

Absorbance Accuracy

1% (0.76 absorbance at 350 nm)

1%

Absorbance Resolution

0.002 Abs

Detector

2048-element linear silicon CCD

-

Path length

1 mm, 0.2 mm, (optional: 0.1 mm, 0.05 mm)

1mm, 0.2mm

Cuvette Dimension

1mm, 2mm, 5mm, 10mm

No Cuvette, No cells

Time Range

5s

Display

Touch Display

Detects Nucleic Acid

0.4 to 3750 ng/μl(optional: 7500,15000, dsDNA)

2 to 15000 ng/μl(dsDNA)

          10 to 15000 ng/μl(dsDNA)

Detects Protein

0.01 mg/ml to 100 mg/ml(optional: 200,400, BSA)

0.1 mg/ml to 100 mg/ml(optional: 200,400, BSA)

0.5 mg/ml to 400 mg/ml(BSA)

Application

nucleic acids, proteins, cell cultures, microarray samples, and UV-VIS full spectrum absorbance scan

nucleic acids, proteins

Dimension

240×210×110 mm

210×170×110 mm

300×200×140 mm

Net Weight

1.92 kg

1.35 kg

2.35 kg

Catalogue No.

58080005-04

58080010-04

58080015-04