Home >> >>>Micro-Spectrophotometer IMS-4400

Micro-Spectrophotometer IMS-4400
Micro-Spectrophotometer IMS-4400

Catalogue number : 5809520-04

Micro-Spectrophotometer IMS-4400 allow instrument with a large concentration of nucleic acid range up to 2 to 27500 ng/μl (DS-DNA), protein range up to 0.01 to 820 mg/ml(BSA) without any samples dilution, with each measurement requiring less than 5 seconds with a pipette and wipe.


Availability : 3-4 Weeks

Availability : Availability : 3-4 Weeks

  • Product Information
  • Features
  • Technical Data

Micro-Spectrophotometer IMS-4400 allow instrument with a large concentration of nucleic acid range up to 2 to 27500 ng/μl (DS-DNA), protein range up to 0.01 to 820 mg/ml(BSA) without any samples dilution, with each measurement requiring less than 5 seconds with a pipette and wipe.

The IMS-4000 offers dynamic full spectrum 190 to 850 nm detection to ensure exact results. Suitable for nucleic acids, proteins, bacteria, cell solutions, microarray samples, and conventional full-wavelength scanning with high accuracy and reproducibility. 

Applications

  • Nucleic Acid: Concentration and purity of DS-DNA, SS-DNA and RNA
  • Protein: Concentration of the protein A280 (1Abs = 1mg/mL), BSA, IgG and lysozyme,  Concentration of protein with protein assay kit (Lowry, BCA and Bradford)
  • Cell Culture: Concentration of suspended cell cultures
  • Conventional full-wavelength scanning:  (190 to 850 nm) absorbance scans
  • Microarray: Concentration of fluorescent dye labeled nucleic acid (microarray), for it can measure the concentration of the nucleic acid and the dye at the same time

  • Built-in Xenon flash lamp and touch display
  • Full spectrum 190 to 850 nm
  • Simple, less expensive, easy to use
  • Fast measurement time in less than 5 seconds.
  • The absorbance range is 0.002 to 150 abs
  • Used 2048-element linear silicon CCD detector
  • Designed for micro-volume 1µl samples
  • No dilutions required, even for high concentration sample
  • Designed with heating and cooling system
  • Support USB and win 10 operating system for data transfer
  • Available as darkroom cuvette & detect platform mode

Model

IMS-4100

IMS-4200

IMS-4400

IMS-4400

Wavelength range

190 to 850 nm

Sample Volume

1 μl

50 μl(available: darkroom cuvette & detect platform mode)

 

 

Heating System

-

RT to 42°C

-

Cooling System

-

4°C to -42°C

Wavelength Accuracy

±1nm

Wavelength Resolution

2nm (FWHM Hg 546nm)

Source

xenon lamp

Repeatability

<±0.5nm

Absorbance Range

0.002-550 (equivalent to 10mm optical path)

Absorbance Accuracy

1% (0.76 absorbance at 350nm)

Sample Base Material

stainless steel and quartz fibre

Detector

2048 linear CCD array

Optical Path length

1//0.1/0.05mm automatic conversion

1/2/5/10mm

Time Range

5s

Display

7-inch Touch Display

Detects Nucleic Acid

2 to 27500 ng/μl (DS-DNA)

Detects Protein

0.01 to 820 mg/ml (BSA)

Application

detect nucleic acids, proteins, bacteria, cell solutions, microarray samples, and conventional full-wavelength scanning

Interface

USB

Operating System

win 10

Catalogue No.

5809505-04

5809510-04

5809515-04

5809520-04